4
4
Configuring the TX 4000 board
Using the configuration utility
After you install the TX 4000 board and the NaturalAccess Signaling Software, you
must assign a CP number to each TX 4000 board. Verify that you have completed
the steps described in the installation summary on page 16 before you proceed to
assigning a CP number on page 22.
To assign a CP number, you will use the txcpcfg utility. Depending on the operating
environment, the txcpcfg utility is located in one of the following directories:
Operating system Directory
Windows Program Files\Dialogic\tx\bin\
UNIX /opt/dialogic/tx/bin/
txcpcfg enables you to perform the following types of changes to the configuration:
Assign a CP number
Add a board
Change a CP number
Move a board
Remove a board
Save configuration changes
For more information about txcpcfg, refer to the Dialogic® TX Series SS7 Boards TX
Utilities Manual.